ESM-BYT User’s Manual
ESM-BYT User’s Manual
2.4.2.1.8 Power Signals
Standby power input: +5.0V nominal. See Electrical Specifications for allowable
input range. If VCC5_SBY is used, all available VCC_5V_SBY pins on the
connector(s) must be used. Only used for standby and suspend functions. May be
left unconnected if these functions are not used in the system design.
Real-time clock circuit-power input. Nominally +3.0V.
2.4.2.1.9 Power & System Management Signals
Indicates system is in Suspend to RAM state. Active low output.
Indicates system is in Suspend to Disk state. Active low output.
Indicates system is in Soft Off state.
Indicates that external battery is low
Power button to bring system out of S5 (soft off), active on rising edge.
System Management Bus bidirectional clock line.
System Management Bus bidirectional data line.
System Management Bus Alert - input can be used to generate an SMI# (System
Management Interrupt) or to wake the system.
Indicates imminent suspend operation.
Power OK from main power supply
Reset button input. Active low input.
PCI Express wake up signal.
General purpose wake up signal.
2.4.2.1.10 LVDS Signals
I2C clock output for LVDS display use.
I2C data line for LVDS display use.
2.4.2.1.11 I2C Signals
General purpose I2C port clock output.
General purpose I2C port data I/O line.